Stair rise and run code limits

The figures most US homes are built to, from the 2021 International Residential Code (IRC), section R311.7 for stairs and R312 for guards. They are a reference. Many states and cities adopt the IRC with changes, or use an older edition, so confirm with your local building department before you build.

Side view of four stair risers with the limits marked: riser height 7 3/4 inches maximum, tread depth 10 inches minimum measured nosing to nosing, nosing 3/4 to 1 1/4 inches, headroom 6 feet 8 inches above the nosing line, handrail 34 to 38 inches above the nosing line.
Riser and tread are measured between the leading edges of the treads. Headroom and handrail height are measured from the sloped line through the nosings.

Summary table

Item2021 IRC figureSection
Riser height7 3/4" maximumR311.7.5.1
Tread depth10" minimum, nosing to nosingR311.7.5.2
Difference between steps in one flight3/8" at most, for both risers and treadsR311.7.5.1, R311.7.5.2
Nosing projection3/4" to 1 1/4" with solid risers. Not needed if treads are 11" or deeperR311.7.5.3
Open risersGap must stop a 4" ball, unless the whole stair rises 30" or lessR311.7.5.1
Headroom6' 8" minimumR311.7.2
Stair width36" minimum clear above the handrailR311.7.1
Rise of one flight151" maximum between floors or landingsR311.7.3
LandingsAt the top and bottom of each stair, at least 36" deepR311.7.6
HandrailOn at least one side when there are 4 or more risers, 34" to 38" highR311.7.8, R311.7.8.1
GuardOpen sides more than 30" above the floor or ground. At least 34" high along stairsR312.1.1, R312.1.2

Riser height

The most a single riser may be is 7 3/4". Riser height is measured straight up from the leading edge of one tread to the leading edge of the next. Within one flight, the tallest riser may be no more than 3/8" taller than the shortest. That rule is why the bottom of a stringer is cut short by the tread thickness: without it, the first step comes out a full tread thickness taller than the rest.

A finished floor added later counts too. If you lay 3/4" flooring at the top after the stairs are built, the top riser gets 3/4" shorter and the flight may fail the 3/8" rule.

Tread depth

Treads must be at least 10" deep, measured level between the front edges of two treads that follow each other. That is the run you lay out on the stringer, not the width of the tread board. A 10" run with a 1" nosing needs tread boards 11" deep.

Nosing

On stairs with solid risers, each tread must stick out past the riser below by 3/4" to 1 1/4". The front edge may have a radius of no more than 9/16" or a bevel of no more than 1/2". If the treads are 11" deep or more, the nosing is optional.

Headroom

There must be at least 6' 8" of clear height above the stairs, measured straight up from the sloped line through the tread nosings. Indoors, this sets how long the floor opening above the stairs has to be. The stair stringer calculator works out that length if you tick the floor opening box.

Width

Stairs must be at least 36" wide, clear, above the handrail. A handrail may stick into that width by up to 4 1/2" on each side.

Height of one flight

One flight may climb no more than 151" (12' 7") before a floor or landing. The 2018 edition set this at 147", so it matters which edition your area uses.

Handrails and guards

Stairs with four or more risers need a handrail on at least one side, its top 34" to 38" above the nosing line. Guards are a separate rule. Any open side of a stair, landing or deck that is more than 30" above the floor or ground below needs one. Along stairs the guard must be at least 34" high above the nosing line, and its openings must stop a 4 3/8" ball.

Commercial stairs follow other rules

These figures are for houses and townhouses covered by the IRC. Commercial and multi-family buildings use the International Building Code (IBC), which allows risers of 4" to 7" and treads of at least 11" (IBC 2021 section 1011.5.2).

Checking your local code

Call or email your building department and ask which edition of the IRC they use and whether they changed section R311.7. Ask whether your stairs need a permit. A deck stair often comes under the deck permit.

Common questions

What is the maximum stair riser height for a house?

7 3/4" under the 2021 IRC, section R311.7.5.1. Some areas set a lower figure, so check locally.

What is the minimum tread depth?

10" under the 2021 IRC, measured nosing to nosing. With a 1" nosing that means tread boards at least 11" deep.

What is the 7-11 rule for stairs?

It means a 7" maximum riser and an 11" minimum tread. Those are the commercial limits in the IBC. Houses under the IRC may use 7 3/4" and 10".

How much can stair steps vary?

No more than 3/8" between the tallest and shortest riser in a flight, and the same for tread depth.

Do two or three steps need a handrail?

Under the 2021 IRC, a handrail is required once a flight has four or more risers. Two or three risers don't need one, though a guard may still be needed if the side is more than 30" above the ground.

How much headroom do stairs need?

At least 6' 8", measured straight up from the line through the tread nosings to the lowest thing above, such as the edge of the floor opening or a beam.